Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Interventional Radiology(Electronic Edition) ›› 2015, Vol. 03 ›› Issue (04): 207-210. doi: 10.3877/cma.j.issn.2095-5782.2015.04.009

Special Issue:

• Nonvascular Intervention • Previous Articles     Next Articles

Percutaneous interventional treatment under fluoroscopy for common duct stones after operation of malignant digestive tract tumors

Quanjun Yao1, Hongtao Hu1, Hailiang Li1,(), Chenyang Guo1, Xiang Geng1, Yanan Li1   

  1. 1. Department of Radiology, Henan Provincial Cancer Hospital& Affiliated Cancer Hospital of Zhengzhou University, Zhengzhou 450008, China
  • Received:2015-06-12 Online:2015-11-01 Published:2015-11-01
  • Contact: Hailiang Li
  • About author:
    Corresponding author: Li Hailiang, Email:

Abstract:

Objective

To investigate the clinical effect and complication of percutaneous interventional treatment under fluoroscopy for common duct stones after operation of malignant digestive tract tumors.

Methods

Seven patients were evaluated with common duct stones after operation of malignant digestive tract tumors.All the patients underwent percutaneous interventional treatment under fluoroscopy by stone-removing baskets.

Results

All the treatment were performed successfully and the total bilirubin(TBIL) decreased to the normal range a week later. There were no recurrence of common duct stones in all cases at least six months later. A small amount of biliary tract bleeding was observed in one case and mild abdominal pain occurred in another case. No serious complications were observed.

Conclusions

Percutaneous interventional treatment under fluoroscopy may be a safe and effective method with few complication for common duct stones.

Key words: Under fluoroscopy, Percutaneous interventional treatment, Common duct stones